The X-Rite 508 Spectrodensitometer brings the newest color control technology to a device designed specifically for basic 4-color reproduction.
Spectral technology gives the 508 unmatched performance in monitoring basic quality control for process color print jobs.The unit goes anywhere to quickly measure common density and dot functions.The 508 is ideal for basic commercial, publication packaging, and newspaper printing operations.
The 508 Is Ideal For Basic Prepress Applications
It measures GATF proofing bars, QuarkXPress® color bars, Ugra/Fogra color control elements and other quality control targets used during the prepress process.
The 508 Is Ideal For Newspapers
X-Rite includes specialized 4-color newsprint functions within the 508 to ensure color accuracy and consistency across press runs and over time. These include newsprint-specific density functions and gray balance.The 508 achieves precise color quality control with newsprint and inserts by simultaneously measuring the densities of cyan, magenta, and yellow in a special News mode. Simply measure a three-color gray bar, masthead, banner, weather map, or another color element. The 508 instantly informs you whether any of the colors need adjusting.
Spectrally Based
All of X-Rite’s 500 Series models capture high-resolution spectrophotometric data, which is used as the basis for all of our color and density values. X-Rite’s spectral technology produces the highest level of inter-instrument agreement available in densitometers today.This means you can trust X-Rite’s 500 Series technology to give you the most accurate, consistent, comparable color measurements from different presses, among suppliers, between customer and the printing facility, and from two or more printing sites.
Large Interactive Display
The 508 boasts a large, crisp graphic display configurable for left- or right-handed operation.This same high-resolution display also features full menu commands in multiple languages, to meet the needs of most any location (including English, French, German, Italian, Portuguese, Spanish, Chinese and Japanese plus additional languages).
Intelligent User Interface
An intuitive key-pad uses universally understood up/down arrow keys and a select key to easily navigate menu items. For efficiency, we also included a “back” key, and an “escape” key, which quickly and easily takes users back to the main menu.
On Target
Another X-Rite first is our unprecedented microspot aperture size that is as small as 1.6mm x 3.2mm. This option makes short work of targeting special-color or density measurements. Just locate a bar code, some solid type, or a graphic element and quickly check the color.
Ergonomic Design
All of our new hand-held instruments apply ergonomic concepts to fit naturally in your hand.The targeting shoe clearly pinpoints the measurement area so you get the right measurement every time.
Rugged Construction
The 500 Series instruments absorb the inevitable bumps of everyday use.The 500 Series carries the tradition of being perhaps the most durable instruments in the industry.You will get years of accurate and reliable performance.
User Interface
•Sharp/reversible display
•Left- or right-hand operation
•Interactive menu and key system
•Clear recognition of function when measuring
•Auto color select
•High resolution LCD display
•Multiple language support
•Calibration Alert feature
Security
•Lock out of specified functions
•Lock out of configuration menu
•Security cable (optional)
Density Features
•Density (absolute or minus paper)
•Density Difference (16 reference values)
•Dot Area (Tone Value)
•Dot Gain w/triple reference
•News mode
•Selectable User Configuration (US, Euro, NewsBalance, News3-Color)
•Selectable Status Response (T, E, I,A, G,Tx, Ax, Ex, & Hi-Fi)
Accessories Provided
•Calibration Reference
•Getting Started Guide
•CD Operator’s Manual with Training Video
•AC Adapter
•Carrying Case
•3 year warranty
Note: X-Rite calibration references are traceable to the U.S. National Institute of Standards and Technology through Munsell Color Science Laboratory RIT.
Options
•Polarization Filter (not available on 2.0mm version)
•Ultra Violet Filter
•2.0mm Aperture (not available with polarized version)
•6.0mm Aperture
•Microspot Aperture 1.6mm x 3.2mm (available as factory option only)
•RS-232 Interface Kit
•Security Cable
•External battery charger and extra battery
•Extended warranty coverage (contact factory)
Specifications
Measurement Geometry
45°/0° per ANSI, DIN & ISO
Standards
Spot Size at Sample
3.4mm (.13in) standard
2mm (.078in)
6mm (.236in) optional
1.6mmH (.051 in.) x 3.2mmW
Micro-Spot (.102 in.)
Light Source
Gas Pressure @ 2856°
Response Types
T, E, I, A, G,Tx, Ax, Ex, Hi-Fi
Measurement Range
0.00D–2.5D; 0–160%R
Measurement Time
Approx. 1.4 seconds, approx.
.9 seconds for consecutive
measurements in Speed Read
mode
Warm Up Time
None
Repeatability
±0.005D 0–2.0D*
±0.010D 2.0–2.5D*
*Polarized Yellow ±0.010D 0–1.8D
Micro-Spot ±0.010D 0.0–1.8D
Inter-Instrument Agreement
0.01D or 1% for typical
printing processes
Data Interface
RS-232 serial interface
with baud rates from 1200 to
57.6K communication
Power Source
Ni-MH battery pack,
4.8v rated @ 1650mAH
Charge Time
Approximately 3 hours
Environmental
+10°–35°C operating,
30%–85%RH non condensing
Physical
Dimensions
Height: 81mm (3.2in)
Width: 76mm (3.0in)
Length: 197mm (7.8in)
Weight
1050 grams (2.3lbs.)
An Affordable Solution For
Basic 4-Color Quality Control
The X-Rite 508 Spectrodensitometer brings the newest color control technology to a device designed specifically for basic 4-color reproduction.
Spectral technology gives the 508 unmatched performance in monitoring basic quality control for process color print jobs.The unit goes anywhere to quickly measure common density and dot functions.The 508 is ideal for basic commercial, publication packaging, and newspaper printing operations.
The 508 Is Ideal For Basic Prepress Applications
It measures GATF proofing bars, QuarkXPress® color bars, Ugra/Fogra color control elements and other quality control targets used during the prepress process.
The 508 Is Ideal For Newspapers
X-Rite includes specialized 4-color newsprint functions within the 508 to ensure color accuracy and consistency across press runs and over time. These include newsprint-specific density functions and gray balance.The 508 achieves precise color quality control with newsprint and inserts by simultaneously measuring the densities of cyan, magenta, and yellow in a special News mode. Simply measure a three-color gray bar, masthead, banner, weather map, or another color element. The 508 instantly informs you whether any of the colors need adjusting.
Spectrally Based
All of X-Rite’s 500 Series models capture high-resolution spectrophotometric data, which is used as the basis for all of our color and density values. X-Rite’s spectral technology produces the highest level of inter-instrument agreement available in densitometers today.This means you can trust X-Rite’s 500 Series technology to give you the most accurate, consistent, comparable color measurements from different presses, among suppliers, between customer and the printing facility, and from two or more printing sites.
Large Interactive Display
The 508 boasts a large, crisp graphic display configurable for left- or right-handed operation.This same high-resolution display also features full menu commands in multiple languages, to meet the needs of most any location (including English, French, German, Italian, Portuguese, Spanish, Chinese and Japanese plus additional languages).
Intelligent User Interface
An intuitive key-pad uses universally understood up/down arrow keys and a select key to easily navigate menu items. For efficiency, we also included a “back” key, and an “escape” key, which quickly and easily takes users back to the main menu.
On Target
Another X-Rite first is our unprecedented microspot aperture size that is as small as 1.6mm x 3.2mm. This option makes short work of targeting special-color or density measurements. Just locate a bar code, some solid type, or a graphic element and quickly check the color.
Ergonomic Design
All of our new hand-held instruments apply ergonomic concepts to fit naturally in your hand.The targeting shoe clearly pinpoints the measurement area so you get the right measurement every time.
Rugged Construction
The 500 Series instruments absorb the inevitable bumps of everyday use.The 500 Series carries the tradition of being perhaps the most durable instruments in the industry.You will get years of accurate and reliable performance.
User Interface
•Sharp/reversible display
•Left- or right-hand operation
•Interactive menu and key system
•Clear recognition of function when measuring
•Auto color select
•High resolution LCD display
•Multiple language support
•Calibration Alert feature
Security
•Lock out of specified functions
•Lock out of configuration menu
•Security cable (optional)
Density Features
•Density (absolute or minus paper)
•Density Difference (16 reference values)
•Dot Area (Tone Value)
•Dot Gain w/triple reference
•News mode
•Selectable User Configuration (US, Euro, NewsBalance, News3-Color)
•Selectable Status Response (T, E, I,A, G,Tx, Ax, Ex, & Hi-Fi)
Accessories Provided
•Calibration Reference
•Getting Started Guide
•CD Operator’s Manual with Training Video
•AC Adapter
•Carrying Case
•3 year warranty
Note: X-Rite calibration references are traceable to the U.S. National Institute of Standards and Technology through Munsell Color Science Laboratory RIT.
Options
•Polarization Filter (not available on 2.0mm version)
•Ultra Violet Filter
•2.0mm Aperture (not available with polarized version)
•6.0mm Aperture
•Microspot Aperture 1.6mm x 3.2mm (available as factory option only)
•RS-232 Interface Kit
•Security Cable
•External battery charger and extra battery
•Extended warranty coverage (contact factory)
Specifications
Measurement Geometry
45°/0° per ANSI, DIN & ISO
Standards
Spot Size at Sample
3.4mm (.13in) standard
2mm (.078in)
6mm (.236in) optional
1.6mmH (.051 in.) x 3.2mmW
Micro-Spot (.102 in.)
Light Source
Gas Pressure @ 2856°
Response Types
T, E, I, A, G,Tx, Ax, Ex, Hi-Fi
Measurement Range
0.00D–2.5D; 0–160%R
Measurement Time
Approx. 1.4 seconds, approx.
.9 seconds for consecutive
measurements in Speed Read
mode
Warm Up Time
None
Repeatability
±0.005D 0–2.0D*
±0.010D 2.0–2.5D*
*Polarized Yellow ±0.010D 0–1.8D
Micro-Spot ±0.010D 0.0–1.8D
Inter-Instrument Agreement
0.01D or 1% for typical
printing processes
Data Interface
RS-232 serial interface
with baud rates from 1200 to
57.6K communication
Power Source
Ni-MH battery pack,
4.8v rated @ 1650mAH
Charge Time
Approximately 3 hours
Environmental
+10°–35°C operating,
30%–85%RH non condensing
Physical
Dimensions
Height: 81mm (3.2in)
Width: 76mm (3.0in)
Length: 197mm (7.8in)
Weight
1050 grams (2.3lbs.)