SP64 Tragbares spektrales Kugelgerät
Article number: 31632
Listed in category: Measurement / Remission-Densitometer > SP64 Tragbares spektrales Kugelgerät from brakensiek.de
SP64 Portable spectral unit ball
- Intermediate devices compatibility: 0.10 ΔEcmc.
- Kurzzeitwiederholbarkeit: 0.05 * DELTA.E onto white ceramic
- Panels: 4 mm or 8 mm (switchable); fixed 14 mm (optional)
- Data interface: patented bi-directional RS-232, 300 to 57.600 Baud
Advanced color measurement in laboratory, production and field use
• Lightweight, compact, portable device
• d / 8 ° to DIN 5033
• 0:10 ΔECMC instrument agreement
• Wechelblende with 4 mm and 8 mm spot size or fixed diaphragm with 14 mm
• Large, clear LCD display with graphics function
• Project and Job Functions
• Reclining measuring foot for flexible application
• Simultaneous measurement under Glanzein-exclusion condition and shine
• Robust construction
• Off the line by battery
Measurement functions and indices
The SP64 measuring absolute and differential values for the following colorimetric systems: CIE XYZ, CIE Yxy, CIELAB, Hunter, CIELCH, CMC and Whiteness, Yellowness ASTM E313-98 and 6172nd metamerism index according to DIN The values can be output for each of the nine types of light on the 2 ° and 10 ° standard.
Patented job function and special project functions
The patented job function of SP64, the user can establish clearly defined steps to guide and support the operator. Up to six different, previously defined measurement routines on the PC (work processes) can be loaded into the SP64 from the X-Rite software. About the well-read LCD display, the operator is then guided step by step through his measuring task. Simultaneously, the measurement results for later processing will be saved automatically. The X-Rite SP64 spectrophotometer allows the user to define different color standards, and together on projects.
Pass / Fail Function
The SP64 stores up to 1024 color standards with pass / fail tolerances. The pass / fail rating is displayed on the display as well as red or green LED and an audible signal (when exceeding the tolerance).
Fast color comparison
Quick and easy, the operator can compare the values of two colors. The color control can thus be saving time, without prior data stored and tolerances must be established.
The ball
The integrating sphere of the Spectralon ® SP64 consists of a very stable highly reflective material that withstand tough production conditions. The material is stain resistant and designed to be a detachment or yellowing of the sphere wall coating is excluded. The diffuse reflectance of Spectralon is significantly higher than that of BaSO4 coatings.
Opacity, color strength and color sorting
The SP64 measure opacity as well as three kinds of color, visual, chromatic or Dreibereichswert. The 555 color sorting is possible with the SP64. These are the critical measures Farbqualitätsprüfung in the processing of plastics, textiles and materials with coated surfaces.
Instrument agreement
The SP64 has a superior instrument agreement SP64 especially with other devices. The SP64 provides an excellent agreement with X-Rite's SP62 spectrophotometer. All devices communicate with X-Rite's quality assurance and Rezeptiersoftware on Windows level.
Influence of texture and shine
To determine the influence of texture and shine that SP64 simultaneously measures with and without the gloss component.
Specifications:
Measurement geometry
d / 8 ° to DIN 5033 with X-Rite
DRS measurement
EXCHANGE FOR OPTICAL
• measuring 4 mm / 6 mm
Target Window
• 8 mm measurement / 12 mm
Target Window
Optional fixed optics
• 14 mm measurement / 18 mm
Target Window
LIGHT SOURCE
Gas-filled tungsten lamp
LIGHT TYPES
A, C, D50, D65, D75, F2, F7, F11
and F12
Standard Observer
2 ° and 10 °
RECEIVER
Silicon photodiodes with increased
Blue sensitivity
Spectral
400 nm - 700 nm
SPEKTRALINTERVALLE
10 nm - Measurement
10nm - output
EQUIPMENT COMPLIANCE
4 mm
CIE L * a * b *
0.20 DELTA.E * from average
Deviation of 12 BCRA
Tiles Series II
(Specular component included)
High 0.40 DELTA.E * from a
Tile (specular component included)
CMC comparison
0.15 ΔEcmc average
Deviation of 12 BCRA
Tiles Series II
(Specular component included)
High on a 0.30 ΔEcmc
Tile (specular component included)
8 mm/14 mm
CIE L * a * b *
0.13 DELTA.E * from average
Deviation of 12 BCRA
Tiles Series II (specular component included)
Maximum of 0.25 DELTA.E * from a
Tile (specular component included)
CMC comparison
0.10 ΔECMC average
Deviation of 12 BCRA
Tiles Series II (specular component included)
High 0.20 ΔECMC on
a tile (specular component included)
STORAGE
1024 standards with tolerances
2000 samples
RANGE
0-200% reflectance
Measuring time
Less than 2 seconds
KURZZEITWIEDERHOLBARKEIT
0.05 DE * ab on white ceramic
(Standard deviation)
LAMP
500,000 measurements
POWER SUPPLY
Removable Battery Pack (Nickel-
Metal hydride), 7.2V 1250 mAh
POWER SUPPLY
180-240 VAC, 50-60 Hz, 15 W max
Charging time
about 4 hours - 100% capacity
MEASUREMENTS PER LOAD
1000 measurements within 8
Hours
DATA INTERFACE
Patented bi-directional RS-232,
300-57600 baud
DISPLAY
128 x 256 graphical LCD display
OPERATING
10 ° C to 40 ° C max 85%
relative humidity (non-
condensing)
AUFBEWAHRUNGSTEMPERATUR
-20 ° C to 50 ° C
WEIGHT
1.1 kg
DIMENSIONS
10.9 cm (height), 8.4 cm (width);
19.6 cm (length)
STANDARD EQUIPMENT
Calibration standard, instruction manual,
AC adapter, carrying case
OPTIONAL ACCESSORIES
Battery Charger
Replacement battery pack
- Intermediate devices compatibility: 0.10 ΔEcmc.
- Kurzzeitwiederholbarkeit: 0.05 * DELTA.E onto white ceramic
- Panels: 4 mm or 8 mm (switchable); fixed 14 mm (optional)
- Data interface: patented bi-directional RS-232, 300 to 57.600 Baud
Advanced color measurement in laboratory, production and field use
• Lightweight, compact, portable device
• d / 8 ° to DIN 5033
• 0:10 ΔECMC instrument agreement
• Wechelblende with 4 mm and 8 mm spot size or fixed diaphragm with 14 mm
• Large, clear LCD display with graphics function
• Project and Job Functions
• Reclining measuring foot for flexible application
• Simultaneous measurement under Glanzein-exclusion condition and shine
• Robust construction
• Off the line by battery
Measurement functions and indices
The SP64 measuring absolute and differential values for the following colorimetric systems: CIE XYZ, CIE Yxy, CIELAB, Hunter, CIELCH, CMC and Whiteness, Yellowness ASTM E313-98 and 6172nd metamerism index according to DIN The values can be output for each of the nine types of light on the 2 ° and 10 ° standard.
Patented job function and special project functions
The patented job function of SP64, the user can establish clearly defined steps to guide and support the operator. Up to six different, previously defined measurement routines on the PC (work processes) can be loaded into the SP64 from the X-Rite software. About the well-read LCD display, the operator is then guided step by step through his measuring task. Simultaneously, the measurement results for later processing will be saved automatically. The X-Rite SP64 spectrophotometer allows the user to define different color standards, and together on projects.
Pass / Fail Function
The SP64 stores up to 1024 color standards with pass / fail tolerances. The pass / fail rating is displayed on the display as well as red or green LED and an audible signal (when exceeding the tolerance).
Fast color comparison
Quick and easy, the operator can compare the values of two colors. The color control can thus be saving time, without prior data stored and tolerances must be established.
The ball
The integrating sphere of the Spectralon ® SP64 consists of a very stable highly reflective material that withstand tough production conditions. The material is stain resistant and designed to be a detachment or yellowing of the sphere wall coating is excluded. The diffuse reflectance of Spectralon is significantly higher than that of BaSO4 coatings.
Opacity, color strength and color sorting
The SP64 measure opacity as well as three kinds of color, visual, chromatic or Dreibereichswert. The 555 color sorting is possible with the SP64. These are the critical measures Farbqualitätsprüfung in the processing of plastics, textiles and materials with coated surfaces.
Instrument agreement
The SP64 has a superior instrument agreement SP64 especially with other devices. The SP64 provides an excellent agreement with X-Rite's SP62 spectrophotometer. All devices communicate with X-Rite's quality assurance and Rezeptiersoftware on Windows level.
Influence of texture and shine
To determine the influence of texture and shine that SP64 simultaneously measures with and without the gloss component.
Specifications:
Measurement geometry
d / 8 ° to DIN 5033 with X-Rite
DRS measurement
EXCHANGE FOR OPTICAL
• measuring 4 mm / 6 mm
Target Window
• 8 mm measurement / 12 mm
Target Window
Optional fixed optics
• 14 mm measurement / 18 mm
Target Window
LIGHT SOURCE
Gas-filled tungsten lamp
LIGHT TYPES
A, C, D50, D65, D75, F2, F7, F11
and F12
Standard Observer
2 ° and 10 °
RECEIVER
Silicon photodiodes with increased
Blue sensitivity
Spectral
400 nm - 700 nm
SPEKTRALINTERVALLE
10 nm - Measurement
10nm - output
EQUIPMENT COMPLIANCE
4 mm
CIE L * a * b *
0.20 DELTA.E * from average
Deviation of 12 BCRA
Tiles Series II
(Specular component included)
High 0.40 DELTA.E * from a
Tile (specular component included)
CMC comparison
0.15 ΔEcmc average
Deviation of 12 BCRA
Tiles Series II
(Specular component included)
High on a 0.30 ΔEcmc
Tile (specular component included)
8 mm/14 mm
CIE L * a * b *
0.13 DELTA.E * from average
Deviation of 12 BCRA
Tiles Series II (specular component included)
Maximum of 0.25 DELTA.E * from a
Tile (specular component included)
CMC comparison
0.10 ΔECMC average
Deviation of 12 BCRA
Tiles Series II (specular component included)
High 0.20 ΔECMC on
a tile (specular component included)
STORAGE
1024 standards with tolerances
2000 samples
RANGE
0-200% reflectance
Measuring time
Less than 2 seconds
KURZZEITWIEDERHOLBARKEIT
0.05 DE * ab on white ceramic
(Standard deviation)
LAMP
500,000 measurements
POWER SUPPLY
Removable Battery Pack (Nickel-
Metal hydride), 7.2V 1250 mAh
POWER SUPPLY
180-240 VAC, 50-60 Hz, 15 W max
Charging time
about 4 hours - 100% capacity
MEASUREMENTS PER LOAD
1000 measurements within 8
Hours
DATA INTERFACE
Patented bi-directional RS-232,
300-57600 baud
DISPLAY
128 x 256 graphical LCD display
OPERATING
10 ° C to 40 ° C max 85%
relative humidity (non-
condensing)
AUFBEWAHRUNGSTEMPERATUR
-20 ° C to 50 ° C
WEIGHT
1.1 kg
DIMENSIONS
10.9 cm (height), 8.4 cm (width);
19.6 cm (length)
STANDARD EQUIPMENT
Calibration standard, instruction manual,
AC adapter, carrying case
OPTIONAL ACCESSORIES
Battery Charger
Replacement battery pack
new products