EonStor A16F RS1211
Article number: 32821
Listed in category: IT Systems / Enterprise Storage Solutions (RAID, SAN, NAS) > EonStor A16F RS1211 from brakensiek.de
EonStor A16F-R/S1211
* FC-to-SATA RAID Subsystem
* Two 2Gbps hub embedded Fibre Channel host channels per controller
* One 2Gbps hub Fibre Channel expansion channel per controller for SATA JBOD expansion
* Highest density, 16 drives in 3U rack space
* Auto switch cache policy and Auto shutdown
* Dual-active controllers capable of host-transparent failover/failback
* Up to 64TB capacity per Logical Drive (LD) (OS dependent)
Configuration Model Form Factor ODM/SI Board
Dual-redundant A16F-R1211 3U IFT-7265R-16F2D
Single controller A16F-S1211 3U IFT-7265R-16F2D
Specifications
RAID
Multiple arrays configurable with dedicated or global hot spares
RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, NRAID and JBOD
Online expansion by
1. Adding new drives
2. Copying and replacing drives with drives of larger capacity
Automatic background rebuild
Configurable stripe size and write policy per array
Intelligent Drive Handling
* In degraded mode: Skipping irreparable blocks to continue rebuild
* In normal operation: Data block verification and repair
System Components
Redundant, hot-swappable components, designed for no single point of failure
* One (1) EonStor 3U RAID subsystem enclosure
* One (1) RAID controller module [EonStor A16F-S1211] or
Two (2) RAID controller modules [EonStor A16F-R12112]
* One (1) 256MB(or above) SDRAM DIMM module (pre-installed on the controller module) per controller module
* Two (2), hot-swappable, redundant, 460W power supply units
* Two (2), hot-swappable, redundant, dual-fan, cooling modules
* Sixteen (16), hot-swappable, drive trays each with a preinstalled MUX kit
* One (1) LCD panel (pre-installed on the left side front handle)
* Two (2) front handles
Management
Firmware-embedded Java-based GUI RAID manager
Centralized management of multiple arrays over in-band or Ethernet
Real-time event notification over Email, LAN broadcast, or SNMP traps
Host-side SES emulation with pass-through to back-end SES emulation
SNMP 2.0 MIBs with get and set commands
Firmware-embedded utility via LCD keypad or RS-232C (audio jack) serial port
Module status LED indicators
* Two (2) per drive tray
* Two (2) per cooling module
* One (1) per power supply unit
* Eleven (11) per RAID controller module
Onboard alarm is triggered when one of the following modules fails:
* RAID controller module
* Cooling modules
* Power supply unit
* Hard drive
* Serial port communication with PC hyper-terminal
Drive Interface
Up to 1024 LUNs if sufficiently large memory is used with the proper settings
Supports 3.5", 1" high hard disk drives
Sixteen (16) hot-swappable drive trays
Single dual loop across 16 drives within enclosure
Automatic bad sector reassignment
Drive hot-swappable via SCA-II connectors
Dedicated bandwidth to each connected drive
Host Interface
Auto-negotiate FC-AL, point-to-point, and switched fabric
Concurrent I/O commands
Tagged Command queuing up to 256
Variable stripe size per logical drive
Optimization setting for random or sequential I/Os
Maintenance & Availability
Firmware rolling upgrade on redundant RAID controllers
Synchronized cache over dedicated Fibre channel
Comes standard with a Li-ION battery module
Immediate array availability
Drive roaming, array configuration on drives
Controller voltage and temperature self-diagnostics
Auto switch cache policy and Auto shutdown
When a RAID controller detects conditions exceeding preset thresholds, the following actions will be exerted to protect the hardware:
1. The cached data will automatically be flushed and the array's caching mode will be switched from write-back to write-through
2. Commence an auto shutdown
All environmental thresholds associated with this mechanism are user-configurable and the caching mode changes back to write-back once normal conditions are restored.
Physical/Electrical
Interfaces:
* Five (5) SFP sockets per controller module that use short-wavelength adapters
* One (1) RJ-45 Ethernet port per controller module
* Two (2) RS-232C (Audio Jack) serial ports (38400, n, 8, 1) per controller module (one is for terminal emulation, the other is for UPS support)
Power Supply Unit (PSU) modules:
Two (2) redundant, hot-swappable, 460W, PSU modules with PFC.
Input: 90 ~ 260VAC
47 ~ 63Hz
Output: (Maximum output: 460 Watts)
+12.0V 32A max.
+ 5.0V 25A max.
+ 3.3V 20A max.
Dimensions: 248.9D x 128.8W x 81.6H mm
Cooling Modules:
Two (2), redundant, hot-swappable, dual-fan, cooling modules
Fan speed: 3600rpm
Fan size: 9.7cm
Airflow per cooling module: 61 CFM
* Note there are a total of four fans (two in each cooling module)
Environmental Specifications:
Operating temperature: 5 to 40°C
Non-operating temperature: - 40º to 60ºC
Relative humidity: 10~95%, non-condensing
Operating altitude: sea level to 10,000ft
Dimensions:
* Without protrusions: 131H x 446.2W x 500D mm
* With protrusions: 131H x 485W x 532D mm
Package dimensions: 476H x 592W x 695D mm
System weight (w/o drives):
* Net weight: 20kg
* Gross weight: 32kg
* FC-to-SATA RAID Subsystem
* Two 2Gbps hub embedded Fibre Channel host channels per controller
* One 2Gbps hub Fibre Channel expansion channel per controller for SATA JBOD expansion
* Highest density, 16 drives in 3U rack space
* Auto switch cache policy and Auto shutdown
* Dual-active controllers capable of host-transparent failover/failback
* Up to 64TB capacity per Logical Drive (LD) (OS dependent)
Configuration Model Form Factor ODM/SI Board
Dual-redundant A16F-R1211 3U IFT-7265R-16F2D
Single controller A16F-S1211 3U IFT-7265R-16F2D
Specifications
RAID
Multiple arrays configurable with dedicated or global hot spares
RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, NRAID and JBOD
Online expansion by
1. Adding new drives
2. Copying and replacing drives with drives of larger capacity
Automatic background rebuild
Configurable stripe size and write policy per array
Intelligent Drive Handling
* In degraded mode: Skipping irreparable blocks to continue rebuild
* In normal operation: Data block verification and repair
System Components
Redundant, hot-swappable components, designed for no single point of failure
* One (1) EonStor 3U RAID subsystem enclosure
* One (1) RAID controller module [EonStor A16F-S1211] or
Two (2) RAID controller modules [EonStor A16F-R12112]
* One (1) 256MB(or above) SDRAM DIMM module (pre-installed on the controller module) per controller module
* Two (2), hot-swappable, redundant, 460W power supply units
* Two (2), hot-swappable, redundant, dual-fan, cooling modules
* Sixteen (16), hot-swappable, drive trays each with a preinstalled MUX kit
* One (1) LCD panel (pre-installed on the left side front handle)
* Two (2) front handles
Management
Firmware-embedded Java-based GUI RAID manager
Centralized management of multiple arrays over in-band or Ethernet
Real-time event notification over Email, LAN broadcast, or SNMP traps
Host-side SES emulation with pass-through to back-end SES emulation
SNMP 2.0 MIBs with get and set commands
Firmware-embedded utility via LCD keypad or RS-232C (audio jack) serial port
Module status LED indicators
* Two (2) per drive tray
* Two (2) per cooling module
* One (1) per power supply unit
* Eleven (11) per RAID controller module
Onboard alarm is triggered when one of the following modules fails:
* RAID controller module
* Cooling modules
* Power supply unit
* Hard drive
* Serial port communication with PC hyper-terminal
Drive Interface
Up to 1024 LUNs if sufficiently large memory is used with the proper settings
Supports 3.5", 1" high hard disk drives
Sixteen (16) hot-swappable drive trays
Single dual loop across 16 drives within enclosure
Automatic bad sector reassignment
Drive hot-swappable via SCA-II connectors
Dedicated bandwidth to each connected drive
Host Interface
Auto-negotiate FC-AL, point-to-point, and switched fabric
Concurrent I/O commands
Tagged Command queuing up to 256
Variable stripe size per logical drive
Optimization setting for random or sequential I/Os
Maintenance & Availability
Firmware rolling upgrade on redundant RAID controllers
Synchronized cache over dedicated Fibre channel
Comes standard with a Li-ION battery module
Immediate array availability
Drive roaming, array configuration on drives
Controller voltage and temperature self-diagnostics
Auto switch cache policy and Auto shutdown
When a RAID controller detects conditions exceeding preset thresholds, the following actions will be exerted to protect the hardware:
1. The cached data will automatically be flushed and the array's caching mode will be switched from write-back to write-through
2. Commence an auto shutdown
All environmental thresholds associated with this mechanism are user-configurable and the caching mode changes back to write-back once normal conditions are restored.
Physical/Electrical
Interfaces:
* Five (5) SFP sockets per controller module that use short-wavelength adapters
* One (1) RJ-45 Ethernet port per controller module
* Two (2) RS-232C (Audio Jack) serial ports (38400, n, 8, 1) per controller module (one is for terminal emulation, the other is for UPS support)
Power Supply Unit (PSU) modules:
Two (2) redundant, hot-swappable, 460W, PSU modules with PFC.
Input: 90 ~ 260VAC
47 ~ 63Hz
Output: (Maximum output: 460 Watts)
+12.0V 32A max.
+ 5.0V 25A max.
+ 3.3V 20A max.
Dimensions: 248.9D x 128.8W x 81.6H mm
Cooling Modules:
Two (2), redundant, hot-swappable, dual-fan, cooling modules
Fan speed: 3600rpm
Fan size: 9.7cm
Airflow per cooling module: 61 CFM
* Note there are a total of four fans (two in each cooling module)
Environmental Specifications:
Operating temperature: 5 to 40°C
Non-operating temperature: - 40º to 60ºC
Relative humidity: 10~95%, non-condensing
Operating altitude: sea level to 10,000ft
Dimensions:
* Without protrusions: 131H x 446.2W x 500D mm
* With protrusions: 131H x 485W x 532D mm
Package dimensions: 476H x 592W x 695D mm
System weight (w/o drives):
* Net weight: 20kg
* Gross weight: 32kg